>>Piezo-Driven Nanopositioning & Scanning Systems Catalog Download Site

>>Piezo Nanopositioning Systems   >>Piezo Tilt Platforms   >>Piezo Actuators   >>Piezo Motors   >>Piezo Drivers and Controllers   >>Piezo Actuator Tutorial   >>Precision Actuators  
 

 

The Latest Information on Piezo Nanopositioning Systems is Available Here

P-720, P-721 PIFOCÒ Microscope Objective NanoPositioners & Scanners


P-720, P-721 PIFOCÒ Objective NanoScanners
P-720/P-721 PIFOCÒ Microscope Objective NanoPositioners are fast and compact drive units which can be mounted on most microscopes. The units are screwed between the turret and the objective, providing a positioning and scanning range of up to 100 µm with sub-nanometer resolution while extending the optical path by only 13 mm (infinity corrected microscope required; extension tubes are available to adjust path lengths of other objectives on the turret). Standard thread is W 0.8x1/36", alternate threads are ordered separately. For larger positioning ranges see models P-722 & P-723.

In open loop, the vertical position of the objective roughly corresponds to the drive voltage (see "Tutorial: Piezoelectrics in Positioning" section for behavior of open loop piezos). The open loop models P-720 / P-721.00 are ideal for tracking applications where the position is controlled by data provided by an external sensor (e.g. optical displacement sensor, a CCD camera, etc.). The closed loop versions allow for absolute position control, high linearity and repeatability based on an integrated position feedback sensor.

Application examples:
Scanning interferometry, surface structure analysis, disk drive testing, autofocus systems, confocal microscopy, bio- technology, semiconductor test equipment.

Working principle:
PIFOC positioners are equipped with low voltage piezoelectric drives (0 to 100 V) integrated into a sophisticated flexure guiding system. The force exerted by the piezo drive pushes a flexure parallelogram via an integrated motion amplifier. The wire EDM (Electric Discharge Machining) cut flexures are FEA (Finite Element Analysis) modeled for zero stiction/ friction, ultra-high resolution and exceptional guiding precision.


P-721.10 PIFOCÒObjective NanoScanner on Microscope Turret

Optional threads for P-721.07 and P-721.17:
P-721.02 Thread M26 x 0.75 for P-721.07/17
P-721.03 Thread M27 x 0.75 for P-721.07/17
P-721.04 Thread M28 x 0.75 for P-721.07/17
P-721.05 Thread M32 x 0.75 for P-721.07/17
P-721.06 Thread M26 x 1/36 for P-721.07/17
P-721.08 Thread M19 x 0.75 for P-721.07/17
P-721.11 Thread M25 x 0.75 for P-721.07/17

Objective Extension Tubes:
P-721.90 Objective extension tube, 13 mm, thread W0.8x1/36
P-721.91 Objective extension tube, 13 mm, thread M25 x 0.75
P-721.92 Objective extension tube, 13 mm, thread M26 x 0.75
P-721.93 Objective extension tube, 13 mm, thread M27 x 0.75
P-721.94 Objective extension tube, 13 mm, thread M28 x 0.75
P-721.95 Objective extension tube, 13 mm, thread M32 x 0.75
P-721.96 Objective extension tube, 13 mm, thread M26 x 1/36
P-721.98 Objective extension tube, 13 mm, thread M19 x 0.75

New Piezo Flexure NanoPositioning and Scanning Stage Selection Guide: Click Here

BACK Technical Data Technical Data


Hexapods    Piezo    Nanopositioning Catalog   Capacitive Sensors   Nanopositioning   Micropositioning   PI USA   Piezo-Nanopositioniersysteme
Piezo Linear Actuator  Capacitive Sensor  Micropositioning  Hexapod  Fiber Alignment  Motion Control  High Speed Steering Mirror  Nanopositioning System  Piezo Design  Piezo Driver  Piezo-Driven Nanopositioning & Scanning Systems