PIFOC focus scanner for microscope objectives, high precision, fast step-and-settle, 100 µm, capacitive sensors, D-sub connector
P-725.xCDE2 PIFOC Focus Scanner for Microscope Objectives
Dynamic Scanning with Travel Ranges of 100 µm, 400 µm, or 800 µm
- Travel range 100 µm, 400 µm, or 800 µm
- Significantly faster response and longer lifetime than motorized drives
- Fine positioning of objectives with sub-nm resolution
- Direct position measuring with capacitive sensors: Highest linearity
- Large clear aperture with Ø 29 mm
Application fields
- Super-resolution microscopy
- Light disk microscopy
- Confocal microscopy
- 2-photon microscopy
- 3D imaging
- Screening
- Interferometry
- Measuring technology
- Autofocus systems
- Biotechnology
- Semiconductor inspection
Outstanding lifetime due to PICMA® piezo actuators
The PICMA® piezo actuators are all-ceramic insulated. This protects them against humidity and failure resulting from an increase in leakage current. PICMA® actuators offer an up to ten times longer lifetime than conventional polymer-insulated actuators. 100 billion cycles without a single failure are proven.
Subnanometer resolution with capacitive sensors
Capacitive sensors measure with subnanometer resolution without contacting. They guarantee excellent linearity of motion, long-term stability, and a bandwidth in the kHz range.
High guiding accuracy due to zero-play flexure guides
Flexure guides are free of maintenance, friction, and wear, and do not require lubrication. Their stiffness allows high load capacity and they are insensitive to shock and vibration. They work in a wide temperature range.
Specifications
Datasheet P-725.xCDE2
Specifications
Motion | P-725.1CDE2 | P-725.4CDE2 | P-725.8CDE2 | Tolerance |
---|---|---|---|---|
Active axes | Z | Z | Z | |
Travel range in Z | 100 µm | 400 µm | 800 µm | +20 / -0 % |
Travel range in Z, open loop | 120 µm | 420 µm | 840 µm | ±20 % |
Linearity error in Z | 0.01 % | 0.01 % | 0.02 % | |
Yaw (Rotational crosstalk in θX with motion in Z) | ± 10 µrad | ± 10 µrad | ± 50 µrad | |
Pitch (Rotational crosstalk in θY with motion in Z) | ± 10 µrad | ± 45 µrad | ± 50 µrad | |
Positioning | P-725.1CDE2 | P-725.4CDE2 | P-725.8CDE2 | Tolerance |
Minimum incremental motion in Z | 1 nm | 4 nm | 5 nm | |
Point repeatabilitiy, 10% step, 1 sigma | 10 nm | 10 nm | 50 nm | |
Integrated sensor | Capacitive, direct position measuring | Capacitive, direct position measuring | Capacitive, direct position measuring | |
Sensor noise, 1 sigma | 0.2 nm | 0.2 nm | 0.8 nm | |
Position noise in Z | 0.1 nm | 0.1 nm | 0.4 nm | max. |
Settling time for 10% step in Z | 14 ms | 22 ms | 39 ms | ±10 % |
Drive Properties | P-725.1CDE2 | P-725.4CDE2 | P-725.8CDE2 | Tolerance |
Drive type | PICMA® | PICMA® | PICMA® | |
Electrical capacitance in Z | 3.2 µF | 6.4 µF | 12.8 µF | ±20 % |
Mechanical Properties | P-725.1CDE2 | P-725.4CDE2 | P-725.8CDE2 | Tolerance |
Stiffness in Z | 0.5 N/µm | 0.25 N/µm | 0.07 N/µm | ±20 % |
Resonant frequency in Z, unloaded | 680 Hz | 400 Hz | 230 Hz | ±20 % |
Resonant frequency in Z, under load with 150 g | 290 Hz | 175 Hz | 110 Hz | ±20 % |
Permissible push force in Z | 100 N | 100 N | 100 N | max. |
Permissible pull force in Z | 20 N | 20 N | 20 N | max. |
Guide | Flexure guide with lever amplification | Flexure guide with lever amplification | Flexure guide with lever amplification | |
Overall mass | 280 g | 280 g | 350 g | ±5 % |
Material | Stainless steel, aluminum | Stainless steel, aluminum | Stainless steel, aluminum | |
Objective diameter | 39 mm | 39 mm | 39 mm | max. |
Miscellaneous | P-725.1CDE2 | P-725.4CDE2 | P-725.8CDE2 | Tolerance |
Operating temperature range | 10 to 70 °C | 10 to 70 °C | 10 to 70 °C | |
Connector | D-sub 7W2 (m) | D-sub 7W2 (m) | D-sub 7W2 (m) | |
Cable length | 1.5 m | 1.5 m | 1.5 m | +50 / -0 mm |
Recommended controllers / drivers | E-709.1C1L - economic choice, suitable for most use cases; E-754.1CD - high performance choice for highest precision | E-709.1C1L - economic choice, suitable for most use cases; E-754.1CD - high performance choice for highest precision | E-709.1C1L - economic choice, suitable for most use cases; E-754.1CD - high performance choice for highest precision |
Linearity error: The specified value can only be reached with recommended digital controllers.
Settling time: 1% error band, 150 g load
Position noise: 1 sigma
The objective is not included in the scope of delivery.
All specifications based on room temperature (22 °C ±3 °C).
Downloads
数据表
Datasheet P-725.xCDE2
文件
InstallationInstructions P725UM0002
Thread Adapters for P-725.xCDE2 PIFOC Focus Scanners
3D模型
3-D模型P-725.xCDE2
手册
P-725 PIFOC® Portfolio
Piezobased Objective Focus Drive Series
Ask for a free quote on quantities required, prices, and lead times or describe your desired modification.
PIFOC focus scanner for microscope objectives, high precision, fast step-and-settle, 400 µm, capacitive sensors, D-sub connector
PIFOC focus scanner for microscope objectives, high precision, fast step-and-settle, 800 µm, capacitive sensors, D-sub connector
询问工程师
通过电子邮件或电话从当地PI销售工程师处快速获取解答。
应用
基因组测序
蓝色、棕色还是绿色的眼睛?哪种发色?哪些疾病会影响我们的健康?我是谁的孩子?所有这些信息以及更多信息均存储在或至少根植于我们的基因中。在犯罪小说以及现实生活中,如果要寻找“是谁干的”这一问题的答案,则需要进行基因分析以寻求线索。. “基因指纹”已成为常供参考和明确无误的证据。最后但同样重要的是,基因组分析是获得许多与健康相关问题的突破性发现的关键。
IsoView光片显微镜
光片显微镜是一项具有吸引力的技术,在生命科学和生物技术中有着巨大的应用潜力。IsoView是这项技术的出色诠释,尤其适用于在数小时内对大型标本进行快速细胞动力学成像。标本定位和物镜平移在IsoView的设计中起着重要作用。
GATTAscope (TIRFM)
线性平台在TIRF显微镜中调整激光束。样本的精密定位可通过组合两个XY位移平台来实现。
共聚焦显微镜
共聚焦显微镜通过聚焦面移动来检测样本表面的结构,例如用于皮肤病检测。
光学相干断层扫描
压电陶瓷促动器和驱动器(例如PILine® OEM电机)可确保光学相干断层扫描(OCT)所需的高精度和位置稳定性。
高速显微镜